Ricoh / Infotec / Rex Rotary / Nashuatec / Gestetner / Lanier Fault Codes

 Aficio 200,  Aficio250

SC120: Scanner home position error 1

-Definition- [B]
The scanner home position sensor does not detect the off condition
during initialization or copying.
- Possible causes -
· Scanner home position sensor defective
· Scanner drive motor defective
· IOSCC board defective
· Scanner home position sensor harness defective

SC121: Scanner home position error 2

-Definition- [B]
The scanner home position sensor does not detect the on condition
during initialization or copying.
- Possible causes -
· Scanner home position sensor defective
· Scanner drive motor defective
· IOCSS board defective
· Scanner home position sensor harness defective

SC122: Scanner home position error 3

-Definition- [B]
The scanner home position sensor detects the on condition while the
scanner is returning to the home position.
- Possible causes -
· Scanner home position sensor defective
· Scanner drive motor defective
· IOCSS board defective
· Scanner home position sensor harness defective
SC CODE DESCRIPTIONS 1 August 1996

SC123: Scanner home position error 4

-Definition- [B]
The scanner home position sensor does not detect the on condition after
the scanner returns to the home position.
- Possible causes -
· Scanner home position sensor defective
· Scanner drive motor defective
· IOCSS board defective
· Scanner home position senor harness defective

SC192: Automatic SBU adjustment error

-Definition- [B]
An error is detected during automatic SBU adjustment.
- Possible cause -
· SBU defective
· BiCU board defective
· Lamp regulator defective
· Exposure lamp deective
· Dirty white plate
 
SC302: Charge roller current leak
-Definition- [B]
A charge roller current leak signal is detected.
- Possible causes -
· Charge roller damaged
· Charge high voltage supply board defective
· Poor connection of the PCU
1 August 1996 SC CODE DESCRIPTIONS

SC306: Charge roller home position error

-Definition- [B]
The charge roller contact sensor does not detect the on condition.
- Possible causes -
· Charge roller contact sensor defective
· Charge roller contact clutch defective

SC320: Polygon motor error

-Definition- [B]
The polygon motor does not reach its operating speed within 10 seconds
after the polygon motor on signal, or the lock signal is not detected for
more than 40 ms continuously during operation.
- Possible causes -
· Polygon motor defective
· Poor connection of the interface harness which connects the polygon
motor driver and the IOCSS board
· IOCSS board defective
 
SC321: No laser start signal (F-GATE error)
NOTE: This SC code is only for copy mode.
- Definition- [B]
The CPU does not detect the laser start signal (F-GATE) after the copy
paper reaches the registration sensor.
- Possible causes -
· BiCU board defective
· MSU board defective

SC322: Laser synchronization error

-Definition- [B]
The laser synchronization signal cannot be detected by the main scan
synchroniziation detector board for more than 5 consecutive 100 intervals.
- Possible causes -
· Poor connection of the interface harness which connects the laser
synchronization detector board and the BiCU board
· Laser synchronization detector board out of position
· Laser synchronization detector board defective
· BiCU board defective

SC324: LD drive current over

-Definition- [B]
The LD drive board applies more than 100 mA to the LD.
- Possible causes -
· LD unit defective (not enough power, due to aging)
· Poor connection of the interface harness which connects the LD unit and
the BiCU board
· Temperature around the LD unit is too high

SC390: TD sensor error 1

-Definition- [B]
The TD sensor outputs less than 0.5V, 20 s after the TD sensor initial
setting has been performed.
- Possible causes -
· TD sensor abnormal
· Poor connection of the PCU

SC391: Development bias leak

-Definition- [B]
A development bias leak signal is detected.
- Possible causes -
· Poor connection of the PCU
· High voltage supply board defective

SC393: TD sensor error 2

-Definition- [B]
TD sensor output voltage falls out of the adjustment range (2.0 ± 0.2 V)
after the TD sensor initial setting has been finished.
- Possible causes -
· TD sensor abnormal
· Poor connection of the PCU

SC401: Transfer roller leak error 1

SC402: Transfer roller leak error 2

-Definition- [B]
A transfer roller current leak signal is detected.
- Possible causes -
· High voltage supply board defective
· Poor connection of the PCU
· Transfer roller damaged

SC411: Separation bias error

-Definition- [B]
A separation bias leak signal is detected.
- Possible causes -
· High voltage supply board defective
· Poor connection of the PCU
· Discharge brush defective

SC500: Main motor lock

-Definition- [B]
A main motor lock signal is detected for more than 5 seconds or the lock
signal is not detected for more than 500 ms during rotation.
- Possible causes -
· Too much load on the drive mechanism
· Main motor defective

SC503: Upper tray lift motor malfunction (optional paper tray unit only)

SC504: Lower tray lift motor malfunction (optional paper tray unit only)

-Definition- [C]
The paper upper limit sensor is not activated after the tray lift motor has
been on for 10 seconds.
- Possible causes -
· Upper limit sensor defective
· Tray lift motor defective
· IOCSS board defective

SC506: Paper tray unit main motor lock (optional paper tray unit

only)

-Definition- [C]
A main motor lock signal is detected for more than 5 seconds or the lock
signal is not detected for more than 5 seconds during rotation.
- Possible causes -
· Paper tray unit main motor defective
· Too much load on the drive mechanism

SC542: Fusing temperature warm-up error

-Definition- [A]
The fusing temperature does not reach the fusing standby temperature
within 50 seconds after the main switch is turned on.
- Possible causes -
· Fusing thermistor defective or out of position
· Fusing lamp open
· Fusing thermofuse open
· Power supply board defective
· Poor connection of the fusing unit

SC543: Fusing overheat error

-Definition- [A]
A fusing temperature of over 231°C is detected for 1 second by the fusing
thermistor.
- Possible causes -
· Fusing thermistor defective
· Power supply board defective

SC544: Fusing low temperature error

-Definition- [A]
A fusing temperature of lower 100°C is detected for 1 second by the
fusing thermistor.
- Possible causes -
· Fusing thermistor defective
· Power supply board defective

SC546: Fusing ready temperature malfunction

-Definition- [A]
The fusing temperature goes 10 °C below or 10 °C over the stand-by
temperature after warm-up is completed.
- Possible causes -
· Thermistor defective
· Poor connection of the fusing unit
· Power supply board defective

SC547: Zero cross signal malfunction

-Definition- [A]
Zero cross signals are not detected within a certain period.
- Possible causes -
· Power supply board defective
· IOCSS defective
· BICU defective

SC610: Communication error between IOCSS and duplex unit

-Definition- [B]
The IOCSS board cannot communicate with the duplex unit properly.
- Possible causes -
· Poor connection of the duplex unit
· IOCSS board defective
· Duplex control board defective

SC691: Communication error between BICU and fax controller

-Definition- [B]
The BiCU board cannot communicate with the fax controller properly.
- Possible causes -
· Poor connection of the interface harness which connects the BiCU board
and the fax controller
· BICU board defective
· Fax controller defective

SC692: Communication error between BiCU and printer controller

-Definition- [B]
The BICU board cannot communicate with the printer controller properly.
- Possible causes -
· Poor connection of the interface harness which connects the BICU board
and the mother board.
· Poor connection between the mother board and the printer controller
· BICU board defective
· Printer controller defective
· Mother board defective

SC900: Total counter error

-Definition- [C]
The total counter is not working properly.
- Possible causes -
· Total counter defective
· IOCSS board defective

SC920: MSU connection error

-Definition- [B]
The MSU set signal is not detected
- Possible cause -
· Poor connection between the BICU board and the MSU
· BICU board defective
· MSU defective

SC921: MSU hardware error

-Definition- [B]
The hardware of the MSU is defective
- Possible cause -
· MSU defective
· BICU defective
· Front door safety switch does not work properly

SC980: Program loading error

-Definition- [C]
The program cannot load properly.
- Possible cause -
· Poor connection between the BICU and the ROM board
· BICU board defective
· ROM board or the program defective

SC981: NVRAM clear error

-Definition- [C]
The data stored in the NVRAM is not cleared properly when the Memory
All Clear is performed.
- Possible cause -
· NVRAM defective

SC990: Communication error between BICU and IOCSS board

-Definition- [B]
The BiCU board cannot communicate with the IOCSS board properly.
- Possible cause -
· Poor connection between the BiCU board and the IOCSS board
· BiCU board defective
· IOCSS board defective

SC CODE DESCRIPTIONS 1 August 1996

 
LABOUR RATES
CALL OUT  £17.50
LABOUR £37.50

PER HALF HOUR ALL PRICES EXCLUDE VAT

 
CONTACT US
 
Support Areas
Computer Support
Network Support
Photocopier Support
 

Ricoh, Infotec, Fault Codes SC120, SC121, SC122, SC123, SC192, SC302, SC306, SC320, SC321, SC322, SC324, SC390, SC391, SC393, SC401, SC402, SC411, SC500, SC503, SC504, SC506, SC542, SC543, SC544, SC546,SC547, SC610, SC691, SC692, SC900, SC920,SC921

 

 

CONTACT US
Digital Office Solutions
Unit 5 Hyders Farm
 Bonnetts Lane
Crawley
RH11 0NY
Enquiries
01293 537827
Email Us
SUPPORT
is offered
Monday - Friday
9.00am - 5.30pm
0870 848 4040

 

Introductory discount voucher!

OCT 2014 NEW LABOUR RATES

Callout from £15.00 + vat

£35 + vat per half hour.

Equivalency List

Fault Codes

Cont Form

 

 

UK Photocopier Repairs

 

 

 

 

Quickstream Ltd T/A Digital Office Solutions,
Unit 5 Hyders Farm,
Bonnetts Lane
Crawley, 
RH11 0NY
Telephone 01293 537827 Registered in England Registration Number 04193475
Faxscimile 01293 619934 Registered Office 87 Church Street, Willingdon BN22 0HS
   
Director J M Waters  Vat Registration No 858 1773 84